REQUEST A QUOTE

Tell Us What Your Project Needs

Select a product and tell us the quantity and operating conditions. Add the size, pressure, temperature, material and connection details you already know.

Fuhai Valve · Enquiry

Select a product and tell us the quantity and operating conditions. Add the size, pressure, temperature, material and connection details you already know.

Joe@fuhaivalves.com

WhatsApp +86 150 5807 7999

Valve procurement questions

Clarify standards, pressure ratings, materials and service conditions before comparing valve proposals.

Is ‘ANSI valve’ sufficient on a purchase specification?

No. ANSI coordinates and accredits the American National Standards system; it does not itself develop valve standards. Specify the applicable standard numbers and editions. ASME B16.34 addresses valve pressure–temperature ratings and other requirements, while ASME B16.5 covers pipe flanges and flanged fittings. Define end connections, materials and inspection requirements separately.

How do Class 150, PN and operating pressure differ?

Class and PN are rating designations, not direct statements of operating pressure. Class 150 does not mean that 150 psi is allowable at every temperature. Check the pressure–temperature rating for the applicable standard, material and design temperature, and confirm the limits of the seats and seals. A conversion table alone cannot establish interchangeability between Class-rated and PN-rated components.

How should I select WCB, CF8 or CF8M?

WCB is a carbon steel casting grade; CF8 and CF8M are different austenitic stainless steel casting grades. State the material specification and grade instead of using ‘carbon steel’ or ‘stainless steel’ alone. Selection depends on fluid composition, concentration, temperature and corrosion conditions, together with compatible trim and sealing materials. Neither the stainless steel label nor the CF8M grade alone establishes suitability for a particular fluid.

How should I choose between floating and trunnion-mounted ball valves?

The design name or nominal size alone is insufficient for selection. Specify the fluid, temperature, operating pressure and maximum differential pressure, then confirm seat sealing directions, cavity pressure relief and operating torque.

What should an RFQ include for a technical valve review?

Provide the valve function, type, quantity, nominal size, connection standard and dimensions. State fluid composition, design and operating pressures, temperature range and maximum differential pressure during operation, plus material, sealing, actuation and inspection requirements. Identify hydrogen sulfide, solids or other special conditions. Include available datasheets, piping specifications and project standards. Mark unknown parameters for confirmation instead of filling them with assumptions.

Are API 6D, API 608 and API 607 the same ball-valve design standard?

No. They are separate publications. API 6D specifies requirements for valves, including design, manufacturing, materials, testing, marking and documentation. API 608 is a product standard for metal ball valves with flanged, threaded and welding ends. API 607 addresses fire type-testing of valves under pressure during and after the specified fire test. API 607 and API 608 are not chapters of API 6D, and their designations are not interchangeable. In an RFQ, identify the applicable product standard and edition, and state any fire-test requirement separately. Confirm that supporting documentation covers the proposed valve configuration; mentioning a standard does not establish certification or conformity of a pictured sample.

Can a 1000 WOG marking be used directly as an ASME Class or PN rating?

A WOG marking on a photographed sample does not by itself establish an ASME Class or PN designation. Specify the required rating and verify the applicable pressure-temperature limits, body material, end connections, seats, seals and service conditions against the proposed valve's confirmed datasheet. Keep the pictured marking as a sample reference rather than assuming a Class or PN conversion, a complete size range or suitability for every medium and temperature. Include the required PN or Class, design pressure and temperature in the RFQ, and mark unknown values for confirmation.

This guide provides general selection information. Final selection and acceptance depend on the applicable standard editions, project requirements and confirmed datasheet. The older API purchasing handbook cited here is a reference for procurement inputs, not a statement of the latest requirements.